Water washing titrated acid method

From Biopowered
Revision as of 22:41, 19 October 2012 by KH (talk | contribs) (Solvent for titrating)
Jump to: navigation, search

WarningIconSmall.png This page is Work In Progress and therefore may not be complete.

This is a processing method which allows the biodiesel to be water washed and dried within the processor, therefore it is ideal for those with limited space who may not have the room for separate tanks needed for conventional water washing. To work effectively there needs to be a minimal amount of soap in the biodiesel prior to washing. As such, it is best used with the two stage process with no titration


Introduction to the method

In all biodiesel processes, there is a need to remove the soaps, residual processing chemicals, residual glycerol and any other impurities prior to use. This is normally achieved by either washing them out with water in the water washing process or by driving off the methanol which may or not be recovered and allowing the other products to settle out.

Both of these methods take time and extra space.

The idea of this method is to safely water wash the biodiesel whilst still in the processor and immediately after draining the glycerol, with no risk of creating an emulsion.

The dreaded emulsion or 'Chicken Soup' is created when water and biodiesel mix in the presence of soap - this is, after all, why soap is used to wash oils and greases away with water. Clearly, if we intend to mix water with hundreds of litres of biodiesel and mix vigorously with a pump then the soaps need to be removed, or turned into something else, first.

Once the soaps are gone, the biodiesel can safely be washed and the impurities drained out. However, the biodiesel will still be wet and will need to be dried before use.

The process steps

Producing the biodiesel

The first step is to process the biodiesel by your chosen method. Whilst not essential, the two stage process with no titration method is recommended to minimise the amount of soap to be dealt with. Once as fully converted as possible, drain off all the glycerol. The fuel is now ready for the second step.

Determining the amount of acid needed

Bromothymol blue colours - Wikipedia

It is to carry out a titration of the fuel to ascertain the amount of acid needed to neutralise the residual chemicals and convert any soaps to free fatty acids. The titration fluid needs to be a known concentration of the acid you intend to use for this process.

An indicator needs to be used which will clearly show and basic to acidic change around the neutral point. A suitable indicator which works very well is BromoThymol Blue, the colours of which are shown on the right in acidic (yellow), neutral (green) and basic (blue) conditions.

To carry out the titration, 50ml of Isopropyl Alcohol or Methanol is placed into a beaker. A few drops of the indicator are added which should turn the solution blue. If the IPA or Methanol has become acidic then the solution is 'blanked' by adding one drop of a time of 0.1% Sodium (or Potassium) Hydroxide solution until the solution has a blue colour). Then 1ml of the biodiesel is added and mixed well. The solution will stay blue and may even become a stronger blue colour as the excess catalyst in the biodiesel and any soaps will be basic (alkaline) in nature. The titration fluid is then added slowly and the amount needed to just turn the mixture yellow (acidic) is recorded.

This figure can be used to calculate the volume of acid needed if the strength of the titration fluid and the batch size are known.

Removing the soaps

Sample during first wash/sulphuric-Julian

The third step is to wash the biodiesel with the diluted acid in the processor by mixing with the pump.

If using a weak acid like vinegar then this can be used neat or slightly diluted. If using a strong acid such as concentrated sulphuric acid then this need to be diluted with a substantial amount of water. If doing this, it is VITAL that the concentrated acid is slowly added to the water. If water is added to concentrated Sulphuric Acid, the strongly exothermic reaction will cause the mixture to boil instantly and spit boiling acid out of the container with potentially devastating results.

After mixing, the processor is left to settle and then the acid/water/impurities mixture is drawn off and discarded.

It is important to take a sample immidiately before switching off the processor. This will give an idea when the mixture has settled and also confirmation that a clean split has occurred.

Water washing

First four washes/sulphuric-Julian

The fourth step is to carry out one or more water washes using clean water for short mix periods. This is done until the water comes out clean after settling. The water washes do not need to be mixed for long and will settle very quickly.

The picture on the right shows the progressively improving clarity of the water after each wash.

Drying the biodiesel

The fifth and final step is to dry the biodiesel, after which it is ready for use.


The chemicals needed

Solvent for titrating

Isopropyl alcohol (IPA) or Methanol can be used as the base solvent for the titration tests. The bio diesel needs to dissolve into this solvent which limits the choices,if using methanol you will need to shake well and use as soon as possible. 50 ml of this needs to be placed into a clean glass jar or beaker. The exact quantity does not appear to be critical.

Titration fluid

As with the titration of WVO to find the acid value, the titration fluid needs to be made of the same chemical as you will be using for the acid treatment. If you wish to use vinegar then the titration fluid should be vinegar diluted to a known concentration with water. If you wish to use Sulphuric acid then the titration fluid should be (very) diluted sulphuric acid. With strong acids, a 0.1% solution (ie 1ml of acid in 1l of water) is fine. For weaker acids it may be prudent to make a stronger solution to avoid having to add large volumes to see a colour change.

To prevent issues due to local water harness, it is prudent to use demineralised water when making the titration fluid. If using strong acids, always add the acid to the water, NEVER add the water to the acid.

Indicator Solution

Universal indicator colours

An indicator is needed which will show the change point when the excess catalyst has been neutralised and the soaps converted to Free Fatty Acids. Different indicators change at different points but what we are looking for is the sudden change in pH when the alkaline conditions are fully neutralised and the addition of any more acid causes a sudden swing to acidic conditions. Suitable indicators tried so far include BromoThymol Blue, Bromophenol Blue and Universal Indicator. Indicators need to be in a liquid state in order that a few drops can be added to solvent base prior to the titration.

0.1% Hydroxide Solution

If, when adding the indicator to the solvent base, the indicator shows acidic conditions then the solvent will need to be blanked. Achieving this requires a weak alkaline solution and the 0.1% (1g/l) solution of Sodium Hydroxide or Potassium Hydroxide commonly used of the titration of WVO is ideal. This is added dropwise until the inidicator shows that the solvent is no longer acidic.

Acid

Perhaps the most important of the chemicals - it is the acid which removes the soaps and ultimately prevents and emulsion. Any acid can be used although there are some which are not recommended. Nitric Acid and Hydrofluoric Acid are best avoided for safety reasons. Viable acids range from Vinegar and Citric Acid at the weak end of the scale to Hydrochloric Acid and Sulhuric Acid at the strongest end. 96% Concentrated Sulphuric Acid is readily available from most chemical suppliers fairly cheaply and very little is needed per batch. Vinegar is very readily available and can be sourced cheaply but significantly more will be required per batch.

Water

Water is used for two purposes in this process. Firstly, if using strong acids, it is used to dilute the acid prior to introduction to the processsor.

Secondly, water is used for the subsequent washes of the biodiesel. Normal tap water is fine for this purpose and there do not seem to be any noticeable effects from varying water hardness.



Vinegar

Ok this is the method i used today,we tried universal indicator so we could tell when it changed to pH 7 as we wanted it neutral,we also tried methanol instead of IPA because the IPA we had was acidic


280 LITRE BATCH

(1) Titrate bio

(2) Titration fluid: white vinegar

(3) 25 ml of Methanol and some Universal Indicator,added 10 ml of bio shake, Green to Blue

(4) Then add the titration fluid in drips until the colour changes to green/yellow

(5) Multiply the result by the batch size to get the amount of acid needed e.g. if 0.1ml vinegar used to change colour to neutralize 10ml bio, 10ml vinegar neutralizes 1L 10x280 = 2.8L vinegar

(6) Add to 30 litres of water and mix with the bio for 25 minutes

(7) Take sample for reference


Sample taken immediately after the first wash/vinegar-KH
First wash starting to settle/vinegar-KH







End the page with the headings below...

See also

Use if there are similar pages in the wiki, if not delete.

  • Link within this wiki here
  • Link within this wiki here
  • Link within this wiki here


References

Use if you need to cite reference material you've used , if not delete.

  1. First ref here
  2. Second ref here


Further reading

Use if you can detail any useful reading matter, if not delete.

  • Book details here
  • Book details here
  • Book details here

External links

Use if you can list any useful links on the internet, if not delete.

  • Link outside this wiki here
  • Link outside this wiki here
  • Link outside this wiki here


Originator to sign and date here by using 4 "squiggle marks" sets the main category.