How to make a cheap water test kit,this wont have the accuracy of the well known version but is more portable than a manometer.
 
How to make a cheap water test kit,this wont have the accuracy of the well known version but is more portable than a manometer.
 
The accuracy is reliant on the quailty of the gauges bought.
 
The accuracy is reliant on the quailty of the gauges bought.
  
[[File:KN_water_test_kit_005.jpg|600px|thumb|left|fully assembled]]
+
[[File:KN_water_test_kit_005.jpg|500px|thumb|right|fully assembled]]
  
  
Line 38: Line 31:
  
  
===Assembly instuctions===
+
 
 +
 
 +
==Assembly instuctions==
 
*Put the plumbing together as in the photo with the low pressure gauge on the valved side
 
*Put the plumbing together as in the photo with the low pressure gauge on the valved side
 
*Drill a hole in the stopend
 
*Drill a hole in the stopend
Line 44: Line 39:
 
*Weld one screw cap on
 
*Weld one screw cap on
 
*Drill two holes in the unwelded cap,one for the male stopend,one for the presta valve
 
*Drill two holes in the unwelded cap,one for the male stopend,one for the presta valve
*Fit the stopend through the hole into the Y piece and seal (i used araldite)
+
*Fit the stopend through the hole into the Y piece and seal (I used araldite)
 
*Fit the valve using two of the round nuts that stop the valve creeping and seal
 
*Fit the valve using two of the round nuts that stop the valve creeping and seal
 
*Replace the rubber seal in the lid with a Viton one
 
*Replace the rubber seal in the lid with a Viton one
Line 50: Line 45:
 
*Drop in the marble
 
*Drop in the marble
  
 
+
<gallery caption="General view with lid removed" widths="300px" heights="200px" perrow="2" align="center">
 
 
 
 
 
 
===Pictures===
 
 
 
<gallery caption="Click pictures to enlarge" widths="300px" heights="300px" perrow="2" align="center">
 
 
File:KN_water_test_kit_003.jpg|Gauge assembled
 
File:KN_water_test_kit_003.jpg|Gauge assembled
 
File:KN_water_test_kit_001.jpg|Inside view
 
File:KN_water_test_kit_001.jpg|Inside view
Line 63: Line 52:
 
==Ingredients==
 
==Ingredients==
 
The reagent
 
The reagent
 +
 
Dry solvent
 
Dry solvent
  
This kit will work with Calcium Hydride (CaH2) and Calcium Carbide (CaC2)as the reagent,the Hydride gives a quicker result and produces more gas (hydrogen) but is hard to source whereas Carbide is available from a well known auction site (£15/500g @4/2011 )
+
This kit will work with calcium hydride (CaH2) and calcium carbide (CaC2)as the reagent,the hydride gives a quicker result and produces more gas (hydrogen) but is hard to source whereas carbide is available from a well known internet auction site (£15/500g @4/2011 )
For a dry solvent you can use petrol or white spirits
+
For a dry solvent you can use petrol or white spirits.
  
  
  
 +
==The idea==
 +
The idea is that any water in the test liquid will react with the calcium and produce a gas (hydrogen),the pressure created is registered on the gauges.
 +
The dry solvent dilutes the test liquid and allows any water present to get to the reagent quicker.
  
===The idea===
 
The idea is that any water in the test liquid will react with the calcium and produce a gas (hydrogen),the pressure created is registered on the gauges
 
The dry solvent dilutes the test liquid and allows any water present to get to the reagent quicker
 
  
  
 
+
==The method==
===The method===
+
With my one shown above ive found that 35ml of test liquid and 10ml of dry solvent combined with 7gr of calcium carbide is an ideal amount.
With my one shown above ive found that 35ml of test liquid and 10ml of dry solvent combined with 7gr of Calcium Carbide is an ideal amount.
+
I grind 7 grammes of calcium and place in the small holder inside then put the two liquids into the vessel, screw the lid on and invert and shake (the marble helps the mixing action)there should be an immediate showing on the lower gauge, keep and eye on the gauge and if it looks like its going to go off the scale shut the valve to the lower gauge and read off the higher one.
I grind 7 grammes of calcium and place in the small holder inside then put the two liquids into the vessel,screw the lid on and invert and shake (the marble helps the mixing action)there should be an immediate showing on the lower gauge,keep and eye on the gauge and if it looks like its going to go off the scale shut the valve to the lower gauge and read off the higher one
+
Take the reading at a set amount of time and try to keep the temp of the tests as constant as posible.
Take the reading at a set amount of time and try to keep the temp of the tests as constant as posible
+
The one shown will give a reading from 11 psi with dry oil upto 80 psi with a water content of 4000 ppm.
The one shown will give a reading from 11 psi with dry oil upto 80 psi with a water content of 4000 ppm
+
The cycle valve is for releasing a fast rising pressure or when finished.
The cycle valve is for releasing a fast rising pressure or when finished
 
 
This type of valve has a knurled nut which i leave undone so if the pressure starts to rise too high it can be released by touching a implement such as a screwdriver to it (DO NOT USE YOUR FINGER)
 
This type of valve has a knurled nut which i leave undone so if the pressure starts to rise too high it can be released by touching a implement such as a screwdriver to it (DO NOT USE YOUR FINGER)
  
The Maximum PPM in Vegetable oil is 400
 
The Maximum PPM in Biodiesel is ???
 
  
===Calibrating===
+
==ASTM==
Obviously the more accurate you are with this the better the accuracy of the finished kit
+
The maximum PPM in vegetable oil is <400
I used new vegetable oil and distilled water to make up various PPM mixes and plotted the result on a graph,this is then used when test your liquid,make sure the vessel is cleaned well between tests
 
  
===Warning===
+
The maximum PPM in biodiesel is <500    EN14214
Do not use on a liquid that is obviously wet,i have taken mine above 80psi and when it reaches its limit the gas escapes from the threaded cap BUT there is a danger it could explode at high pressures
 
  
HYDROGEN a highly explosive gas is made using this kit
+
Biodiesel will hold 1500 ppm of water before going cloudy.
  
<gallery caption="Click pictures to enlarge" widths="300px" heights="300px" perrow="2" align="center">
+
==Calibrating==
File:inside.jpg|View of inside the cap
+
Obviously the more accurate you are with this the better the accuracy of the finished kit.
File:Back.jpg|rear view
+
I used new vegetable oil and distilled water to make up various PPM mixes and plotted the result on a graph, this is then used when test your liquid, make sure the vessel is cleaned well between tests.
</gallery>
 
  
==See also==
 
Use if there are similar pages in the wiki, if not delete.
 
  
* Link within this wiki here
+
==Warning==
* Link within this wiki here
+
Do not use on a liquid that is obviously wet, I have taken mine above 80psi and when it reaches its limit the gas escapes from the threaded cap BUT there is a danger it could explode at high pressures.
* Link within this wiki here
 
  
 +
Hydrogen a highly explosive gas is made when using this kit.
  
~~K.H 8/11~~
+
<gallery caption="Rear view of cap showing location of Presta valve" widths="300px" heights="200px" perrow="2" align="center">
 +
File:inside.jpg|View of inside the cap
 +
File:Back.jpg|rear view
 +
</gallery>
  
Add categories ... By using categories your page will get indexed on the wiki main page.
 
  
For Biodiesel ...
 
  
[[Category:Biodiesel]] sets the main category.
+
[[User:KH|KH]] 19:44, 27 August 2011 (BST)
  
 +
[[Category:Biodiesel]]
  
Now select one from the following, deleting the others:
 
 
[[Category:Safety and Testing]]
 
[[Category:Safety and Testing]]
 
 
Do the same for Veg oil ...
 
  
 
[[Category:vegetable oil]]
 
[[Category:vegetable oil]]
  
Select one from the following, and delete the others:
 
 
[[Category:Testing]]
 
[[Category:Testing]]
 
If your page is applicable to both veg and bio, you can have a total of four category listings.
 
 
Please Note:  To get your page indexed on the main page it is necessary, to got to the main page, click the edit tab and then click save.
 

Latest revision as of 18:54, 8 March 2013

How to make a cheap water test kit,this wont have the accuracy of the well known version but is more portable than a manometer. The accuracy is reliant on the quailty of the gauges bought.

fully assembled




Parts list

  • 1/4" pressure gauge 0-15 psi
  • 1/4" pressure gauge 0-100 psi
  • 1/4" Y piece
  • 1/4" Ball valve
  • Bicycle "presta" valve
  • 1/4" male stopend
  • 2 x 43mm solvent weld access plugs
  • 43mm solvent weld joiner
  • Small plastic cap/cup
  • Small marble
  • Viton O ring

Instead of the presta valve and 0-15 gauge you can use a low pressure gauge designed for motorcycle forks which has a button for releasing the pressure

total cost roughly £20 (dependent on gauges used)



Assembly instuctions

  • Put the plumbing together as in the photo with the low pressure gauge on the valved side
  • Drill a hole in the stopend
  • Weld both access plugs to the joiner
  • Weld one screw cap on
  • Drill two holes in the unwelded cap,one for the male stopend,one for the presta valve
  • Fit the stopend through the hole into the Y piece and seal (I used araldite)
  • Fit the valve using two of the round nuts that stop the valve creeping and seal
  • Replace the rubber seal in the lid with a Viton one
  • Glue the small cap to the inside about 3/4" down
  • Drop in the marble

Ingredients

The reagent

Dry solvent

This kit will work with calcium hydride (CaH2) and calcium carbide (CaC2)as the reagent,the hydride gives a quicker result and produces more gas (hydrogen) but is hard to source whereas carbide is available from a well known internet auction site (£15/500g @4/2011 ) For a dry solvent you can use petrol or white spirits.


The idea

The idea is that any water in the test liquid will react with the calcium and produce a gas (hydrogen),the pressure created is registered on the gauges. The dry solvent dilutes the test liquid and allows any water present to get to the reagent quicker.


The method

With my one shown above ive found that 35ml of test liquid and 10ml of dry solvent combined with 7gr of calcium carbide is an ideal amount. I grind 7 grammes of calcium and place in the small holder inside then put the two liquids into the vessel, screw the lid on and invert and shake (the marble helps the mixing action)there should be an immediate showing on the lower gauge, keep and eye on the gauge and if it looks like its going to go off the scale shut the valve to the lower gauge and read off the higher one. Take the reading at a set amount of time and try to keep the temp of the tests as constant as posible. The one shown will give a reading from 11 psi with dry oil upto 80 psi with a water content of 4000 ppm. The cycle valve is for releasing a fast rising pressure or when finished. This type of valve has a knurled nut which i leave undone so if the pressure starts to rise too high it can be released by touching a implement such as a screwdriver to it (DO NOT USE YOUR FINGER)


ASTM

The maximum PPM in vegetable oil is <400

The maximum PPM in biodiesel is <500 EN14214

Biodiesel will hold 1500 ppm of water before going cloudy.

Calibrating

Obviously the more accurate you are with this the better the accuracy of the finished kit. I used new vegetable oil and distilled water to make up various PPM mixes and plotted the result on a graph, this is then used when test your liquid, make sure the vessel is cleaned well between tests.


Warning

Do not use on a liquid that is obviously wet, I have taken mine above 80psi and when it reaches its limit the gas escapes from the threaded cap BUT there is a danger it could explode at high pressures.

Hydrogen a highly explosive gas is made when using this kit.


KH 19:44, 27 August 2011 (BST)