Pump - TAM 120

From Biopowered
Revision as of 21:18, 9 April 2015 by Julian (talk | contribs)
Jump to: navigation, search

TAM120 new design
TAM120 old design



The TAM120 peripheral pump is sold as being compatible with both mineral diesel and biodiesel and suitable for liquid temperatures up 90°C. This coupled with a good performance make it well suited to a small to medium size home processor, although note should be made of the maximum particle size the pump is able to handle.










TAM 120 specifications

  • Voltage 230v
  • Frequency 50Hz
  • Power 1.5KW
  • Speed 2800RPM
  • Duty cycle Continuous
  • Max flow 80lpm @ 0m head
  • Max pressure 7.5 Bar
  • Max suction lift 7 m
  • Inlet 1½" BSP male
  • Outlet fitting 1½" BSP male
  • Max particle tolerance 100 Micron
  • Max liquid temp 90°C

Components

  • Pump Body Cast iron (Painted)
  • Impeller Case Cast iron (Painted)
  • Impeller Case Seal NBR
  • Motor Shaft Seal NBR
  • Impeller Brass
  • Shaft Key and Nut Stainless steel
  • Motor Shaft Stainless steel

TAM 120 problems and repairs

TAM120 burnt out capacitor
TAM120 melted terminal block
TAM120 wiring diagram
TAM120 "hard wired" with a replacement capacitor


Whilst the major mechanical components have proved rugged in service, several examples of terminal boxes cracking and capacitors over heating with subsequent damage to the terminal block have been observed. These issues can be easily remedied using replacement items: see [3D Printed parts and spares]for a stronger design of 3D printed terminal box or replace with a suitable electrical junction box.

Suitable capacitors can be readily acquired from on line auction sites. Original capacitor specification was 40µF ±5%, 450V AC, 50/60Hz. The replacement capacitor must be suitable for continuous duty.

Where the capacitor has melted the terminal block, it's possible to "hard wire" a new capacitor according to the diagram, right. Ensure that suitable insulation is present at all new electrical connections and if in any doubt seek the advise of a qualified electrician.


On later TAM120 the terminal box and capacitor location was altered (as per photo top right of this page), presumably to overcome these issues.