Difference between revisions of "Pump - Tam 105"

From Biopowered
Jump to: navigation, search
(Performance)
 
(44 intermediate revisions by 5 users not shown)
Line 1: Line 1:
 +
<metadesc>TAM105, Biodiesel processor pump, Biodiesel transfer pump, WVO pump, WVO transfer pump, TAM105 instruction manual, TAM 105 parts list</metadesc>
 
[[File:051010262.jpg|250px|thumb|right|TAM 105 centrifugal pump]]
 
[[File:051010262.jpg|250px|thumb|right|TAM 105 centrifugal pump]]
  
Line 22: Line 23:
 
* Weight 7.2kg
 
* Weight 7.2kg
 
* Part No. 7230350
 
* Part No. 7230350
 +
 +
External link to [http://www.machinemart.co.uk/pages/download?d=1F8AE8C5-2C91-458E-B094-4BA86478063B&a=stream Product Manual]
  
 
==Components==
 
==Components==
Line 53: Line 56:
 
* Max Liquid Viscosity Water
 
* Max Liquid Viscosity Water
 
* Ingress Protection IP44
 
* Ingress Protection IP44
 +
* Fuse Rating - 5 Amps
 +
 +
  
 
==Spares==
 
==Spares==
  
 
   
 
   
Spares for this pump are readily available from the main stockists and distributors whose detail can be found on the internet
+
Spares for this pump are readily available from the main stockists and distributors whose details can be found on the internet
 
 
 
 
 
 
 
 
 
 
 
 
[[File:Tam1051-1.jpg]]
 
 
 
  
[[File:Tam1051.jpg]]
+
[[File:Tam105 exploded diagram.jpg]]
  
 
  
Accessories
+
{| class="wikitable"
 +
|-
 +
! ItemNo.
 +
! scope="col" width="80"|Part No.
 +
! scope="col" width="150"|Description
 +
! scope="col" width="97"|   
 +
! ItemNo.
 +
! scope="col" width="80"|Part No.
 +
! scope="col" width="150"|Description
  
Foot Valve Filter 7950561
+
|-
 +
| 1
 +
| HT10501
 +
| Screw
 +
|
 +
| 15
 +
| HT10515
 +
| Capacitor
 +
|-
 +
| 2
 +
| HT10502
 +
| Fill plug
 +
|
 +
| 16
 +
| HT10516
 +
| Terminal cover, 16-A Terminal Box
 +
|-
 +
| 3
 +
| HT10503
 +
| O ring
 +
|
 +
| 17
 +
| -
 +
| Not used
 +
|-
 +
| 4
 +
| HT10504
 +
| Pump body
 +
|
 +
| 18
 +
| HT10518
 +
| Terminal block
 +
|-
 +
| 5
 +
| HT10505
 +
| O ring
 +
|
 +
| 19
 +
| -
 +
| Not used
 +
|-
 +
| 6
 +
| HT10506
 +
| Impeller
 +
|
 +
| 20
 +
| HT10520
 +
| Stator
 +
|-
 +
| 7
 +
| HT10507
 +
| Spring lock
 +
|
 +
| 21
 +
| HT10521
 +
| End cover
 +
|-
 +
| 8
 +
| HT10508
 +
| Mechanical seal
 +
|
 +
| 22
 +
| HT10522
 +
| Fan cover
 +
|-
 +
| 9
 +
| HT10509
 +
| Splash guard
 +
|
 +
| 23
 +
| -
 +
| Not used
 +
|-
 +
| 10
 +
| HT10510
 +
| Front cover
 +
|
 +
| 24
 +
| HT10524
 +
| Bearing 201
 +
|-
 +
| 11
 +
| HT10511
 +
| Bearing 201
 +
|
 +
| 25
 +
| HT10525
 +
| Spring washer
 +
|-
 +
| 12
 +
| HT10512
 +
| Key
 +
|
 +
| 26
 +
| HT10526
 +
| Fan
 +
|-
 +
| 13
 +
| HT10513
 +
| Rotor
 +
|
 +
| 27
 +
| HT10527
 +
| Bolt
 +
|-
 +
| 14
 +
| HT10514
 +
| Screw
 +
|
 +
|
 +
|
 +
|
 +
|}
  
BSP Spigot Hose Connector 7950210
+
When ordering the plastic terminal connection box, Part-Number HT10516 (part 16 in the parts diagram) Ensure the person taking the order is aware that this comprises of both the top lid as well as the terminal box, or you end up with just the lid.
  
I.D. Reinforced Hose for Suction and delivery 7955010
 
  
I.D. Layflat Hose for delivery only 7955110
+
==Accessories==
  
 +
* Foot Valve Filter 7950561
 +
* BSP Spigot Hose Connector 7950210
 +
* I.D. Reinforced Hose for Suction and delivery 7955010
 +
* I.D. Layflat Hose for delivery only 7955110
  
Fuse Rating
 
  
The fuse in the plug must be rated as follows:
 
  
TAM 105 ......... 5 Amps
+
==Maintenance==
  
 +
<gallery caption="Tam 105 impeller replacement" widths="280px" heights="200px" perrow="3" align="center">
 +
File:Tam 01 Rob-b.jpg|Tam 105 with suspected impeller damage.
 +
File:Tam 02 Rob-b.jpg|Remove three screws using an 8mm socket. The metal is too soft for a screw driver. Remove the pump body.
 +
File:Tam 03 Rob-b.jpg|Damaged impeller with bent/broken vanes. New impellers are available from the original supplier for about £9.00 (price at Jan 2012), part number HT10506. The writer bought two because it's suspected this will happen again.
 +
File:Tam 04 Rob-b.jpg|Before removing the impeller, measure the gap between it and the body with feeler gauges.  The central part is not holding the impeller on so gently prise/wiggle the impeller off with a screw driver. Be careful not to loose the key which can drop out.
 +
File:Tam 05 Rob-b.jpg|Install the new impeller ensuring the clearance previously measured is maintained and reassemble.
 +
</gallery>
  
  
 
  
[[User:KH|KH]] 19:35, 11 December 2010 (UTC)[[Category:biodiesel ]]
+
[[User:KH|KH]] 19:35, 11 December 2010 (UTC)
 +
[[Category:Biodiesel]]
 +
[[Category:Processors and equipment]]
 +
[[Category:Vegetable oil]]
 +
[[Category:Filtration & drying equipment]]

Latest revision as of 22:14, 30 November 2014

TAM 105 centrifugal pump


The TAM 105 1" centrifugal pump is the most popular pump for use in biodiesel processers but remember you are buying a pump that is marketed for clean water only,the figures below only apply to water but are good for comparisons.



TAM 105 specifications

  • Motor 230V 50Hz 1ph
  • Power 330Watts
  • Current 1.4Amps
  • Capacitor 8uF 450V
  • Speed 2800rpm
  • Max. Head 35M
  • Max. Lift (Suction) 7M
  • Bore Size 1”BSP
  • Max. Output 40L/min
  • Weight 7.2kg
  • Part No. 7230350

External link to Product Manual

Components

  • Pump Body Cast Iron (Painted)
  • Impellor Case Cast Iron (Painted)
  • Impellor Case Seal NBR
  • Motor Shaft Seal NBR
  • Rotor / Gear / Impellor Brass
  • Shaft Key / Nut Stainless Steel
  • Motor Shaft Stainless

Performance

  • Voltage / Frequency 230v / 50Hz
  • kW 0.33
  • Amps 1.4
  • RPM 2800
  • Duty Cycle Continuous
  • Bypass Valve Y/N N
  • Max Flow 40 lpm @ 0 m head
  • Discharge Pressure 3.5 Bar / 50.75 PSI
  • Max Suction Lift (Dry) None
  • Max Suction Lift (Wet) 7 m
  • Inlet Fitting 1" BSP
  • Outlet Fitting 1" BSP
  • Max Particle Tolerance 100 Micron
  • Max Liquid Temp 90 Celcius
  • Max Room Temp 40 Celcius
  • Thermal Protection Y/N Y
  • Max Liquid Viscosity Water
  • Ingress Protection IP44
  • Fuse Rating - 5 Amps


Spares

Spares for this pump are readily available from the main stockists and distributors whose details can be found on the internet

Tam105 exploded diagram.jpg


ItemNo. Part No. Description ItemNo. Part No. Description
1 HT10501 Screw 15 HT10515 Capacitor
2 HT10502 Fill plug 16 HT10516 Terminal cover, 16-A Terminal Box
3 HT10503 O ring 17 - Not used
4 HT10504 Pump body 18 HT10518 Terminal block
5 HT10505 O ring 19 - Not used
6 HT10506 Impeller 20 HT10520 Stator
7 HT10507 Spring lock 21 HT10521 End cover
8 HT10508 Mechanical seal 22 HT10522 Fan cover
9 HT10509 Splash guard 23 - Not used
10 HT10510 Front cover 24 HT10524 Bearing 201
11 HT10511 Bearing 201 25 HT10525 Spring washer
12 HT10512 Key 26 HT10526 Fan
13 HT10513 Rotor 27 HT10527 Bolt
14 HT10514 Screw

When ordering the plastic terminal connection box, Part-Number HT10516 (part 16 in the parts diagram) Ensure the person taking the order is aware that this comprises of both the top lid as well as the terminal box, or you end up with just the lid.


Accessories

  • Foot Valve Filter 7950561
  • BSP Spigot Hose Connector 7950210
  • I.D. Reinforced Hose for Suction and delivery 7955010
  • I.D. Layflat Hose for delivery only 7955110


Maintenance


KH 19:35, 11 December 2010 (UTC)